ASTM D6272 PDF

ASTM D – Air Permeability of Textile Fabrics . ASTM D – Standard Test Method for Flexural Properties Testing of Unreinforced and Reinforced. The Flexural test ASTM D measures the force required to bend a plastic beam under a four point loading system. The test method is used for reinforced or . ASTM D tests flexural properties of unreinforced and reinforced plastics and electrical insulating materials by four point bending. Learn more.

Author: Gasar Shakalkree
Country: Cayman Islands
Language: English (Spanish)
Genre: Medical
Published (Last): 6 December 2004
Pages: 490
PDF File Size: 2.21 Mb
ePub File Size: 18.72 Mb
ISBN: 804-4-72912-568-6
Downloads: 20629
Price: Free* [*Free Regsitration Required]
Uploader: Dular

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Measure the width and depth of the specimen to the nearest 0.

They shall be this large if signi? The values provided in parentheses are for information only. Due to copyright restrictions, we are not able to provide copies of standards. In order to avoid excessive indentation, or failure due to stress concentration directly under the loading noses, the radii of the loading noses and supports shall be 5. For this reason and other differences in technical content, exercise extreme care if attempting to compare results between the two test methods.

Since this is not always the case, a slight error will be introduced in the use of this equation. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.

NOTE 4—Whenever possible, the original surface of the sheet shall be unaltered. Email addresses can only aastm letters, numbers and the following special characters: Contact Us View Accessories Catalog.

  DISCURSO DE GETTYSBURG DE ABRAHAM LINCOLN PDF

If there are no material speci? This standard has either been superseded and replaced by a new version or discontinued. NOTE 13—The above calculation is not valid if the specimen is slipping excessively between the supports. The value obtained on specimens with machined surfaces may differ from those obtained on specimens with original surfaces.

ASTM International takes no position respecting the validity of asgm patent rights asserted in connection with any item mentioned in this standard.

A superscript epsilon e indicates an editorial change since the last revision or reapproval. We use cookies to improve your browsing experience.

Instron ASTM D Flexural Properties of Plastics and Electrical Insulating Materials – Instron

They are designed with standard and optional features that increase testing efficiency and improve the testing experience for the operator. ASTM D62722 is a test method for the determinations of flexural properties for unreinforced and reinforced plastics.

NOTE 7—Where machine sensitivity is such that specimens of these dimensions cannot be measured, wider specimens or shorter support spans, or both, may be used, provided the support span-to-depth ratio is at least 14 to 1.

Glossary of Materials Testing Terms. Flexural strain measurement — ASTM D requires that the method used to measure strain is not influenced by the compliance of the machine. This test method utilizes a four point loading system applied to a s6272 supported beam. The low operating-force arms of the extensometer reduce the possibility of knife-edge slippage when testing hard aastm smooth surfaced materials. Precision and Bias Specimen width shall not exceed one fourth of the support span for specimens greater than 3.

  CARLO CRACCO LIBRO RICETTE PDF

The loading nose assembly shall be atm the type which will not rotate. The light-weight, rugged cross-brace design eliminates errors caused by physical distortion, while built-in protection ensures that damage is not caused by over-extension.

ASTM D6272

D beam along its lower face. Any test specimen preparation, conditioning, dimensions, r6272 testing parameters covered in the material specification, or both, shall take precedence over those mentioned in this test method. The chamber has internal electric heaters for elevated temperatures and uses external carbon dioxide gas as a coolant for reduced temperatures.

NOTE 3—Any necessary polishing of specimens shall be done only in the lengthwise direction of the specimen. The series of extensometers offers speed of attachment and ease-of-use.

The amount of force applied to the specimen prior to starting the test directly impacts the repeatability of calculations, such as flexural modulus. Software for Series Systems. It is calculated in accordance with Eq 11 or Eq 12 by letting m equal the slope of the secant to the load-de? Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.

Current edition approved July 10, An example of a jig found to be useful is shown in Fig.

For anisotropic materials, flatwise and edgewise specimens may be tested.